Home | Products | Climate Control | Radiators |



T6 RADIATOR
Centrally Connected Radiators
The T6 radiator is the perfect solution for those looking for a heating system that not only provides optimal warmth but also boasts energy efficiency. The T6 ensures a balanced and even heat distribution, creating a comfortable environment in any room.
Plus, its ease of use makes it a favourite among customers. Whether you're looking to upgrade your heating system or just want to stay warm during the chilly winter months, the T6 is the perfect choice for you.
APPLICATIONS:
Home Heating/Cooling and HVAC
Radiator power data in watts, in accordance with DIN EN 442 at (75/65/20) - 75℃ Flow Temperature, 65℃ Return Temperature and 20℃ Room Temperature.
Full list of dimensions and outputs can be found in product downloads.
HxW = Output - 600x400 = 375.6
HxW = Output - 600x600 = 563.4
HxW = Output - 600x800 = 751.2
HxW = Output - 600x1000 = 939
HxW = Output - 600x1200 = 1126.8
HxW = Output - 600x1400 = 1314.6
HxW = Output - 600x1600 = 1502.4
HxW = Output - 600x1800 = 1690.2
HxW = Output - 400x600 = 628.2
HxW = Output - 400x800 = 837.6
HxW = Output - 400x1000 = 1047
HxW = Output - 400x1200 = 1256.4
HxW = Output - 400x1400 = 1465.8
HxW = Output - 400x1600 = 1675.2
HxW = Output - 400x1800 = 1884.6
HxW = Output - 400x2000 = 2094
HxW = Output - 400x2200 = 2303.4
HxW = Output - 400x2400 = 2512.8
HxW = Output - 500x400 = 490.8
HxW = Output - 500x600 = 736.2
HxW = Output - 500x800 = 981.6
HxW = Output - 500x1000 = 1227
HxW = Output - 500x1200 = 1472.4
HxW = Output - 500x1400 = 1717.8
HxW = Output - 500x1600 = 1963.2
HxW = Output - 500x1800 = 2208.6
HxW = Output - 500x2000 = 2454
HxW = Output - 500x2200 = 2699.4
HxW = Output - 500x2400 = 2944.8
HxW = Output - 500x2600 = 3190.2
HxW = Output - 500x2800 = 3435.6
HxW = Output - 500x3000 = 3681
HxW = Output - 600x400 = 542.8
HxW = Output - 600x600 = 814.2
HxW = Output - 600x800 = 1085.6
HxW = Output - 600x1000 = 1357
HxW = Output - 600x1200 = 1628.4
HxW = Output - 600x1400 = 1899.8
HxW = Output - 600x1600 = 2171.2
HxW = Output - 600x1800 = 2442.6
HxW = Output - 600x2000 = 2714
HxW = Output - 600x2200 = 2985.4
HxW = Output - 300x400 = 438
HxW = Output - 300x1000 = 1095
HxW = Output - 300x1200 = 1314
HxW = Output - 300x1400 = 1533
HxW = Output - 300x1600 = 1752
HxW = Output - 400x600 = 814.2
HxW = Output - 400x800 = 1085.6
HxW = Output - 400x1000 = 1357
HxW = Output - 400x1200 = 1628.4
HxW = Output - 400x1400 = 1899.8
HxW = Output - 400x1600 = 2171.2
HxW = Output - 400x1800 = 2442.6
HxW = Output - 400x2000 = 2714
HxW = Output - 400x2200 = 2985.4
HxW = Output - 600x600 = 1027.8
HxW = Output - 600x800 = 1370.4
HxW = Output - 600x1000 = 1713
HxW = Output - 600x1200 = 2055.6
HxW = Output - 600x1400 = 2398.2
HxW = Output - 600x1600 = 2740.8
HxW = Output - 600x1800 = 3083.4
HxW = Output - 600x2000 = 3426
HxW = Output - 600x2200 = 3768.6
HxW = Output - 900x400 = 918.4
HxW = Output - 900x600 = 1377.6
HxW = Output - 900x800 = 1836.8
HxW = Output - 600x600 = 1471.8
HxW = Output - 600x720 = 1766.16
HxW = Output - 600x800 = 1962.4
HxW = Output - 600x1000 = 2453
HxW = Output - 600x1200 = 2943.6
HxW = Output - 600x1400 = 3434.2
HxW = Output - 600x1600 = 3924.8
HxW = Output - 600x1800 = 4415.4
The T6 technology is based on the radiator’s axis of symmetry, thereby creating limitless flexibility. T6 centrally connected radiators are perfectly symmetrical. They are the ideal combination of design and unique technology.
Thanks to the patented technology and the special geometry of the convection plates, the T6 provides extremely high heating power. Consequently, it is able to heat up rooms particularly rapidly and guarantees the optimum level of thermal comfort.
The T6: A Revolution in Radiators
Thanks to innovative centre-connection technology and optimum energy efficiency, the T6 sets the standard for room heating, comfort and ease of use - advantages that will win over any customer!
Connection Advantage
Diagonal or in-line connection via a standardised connection position.

Selection Advantage
Even if the pipework is laid in advance, the choice of radiator can be changed at any time.

Positioning Advantage
Flexible thermostat position as desired, thanks to patented pipe guides.

Installation Advantage
Cost-effective, attractive and safe installation options without limitations.

Distance Advantage
Flexible choice of models with a standardised distance between the connection and the wall.

Assembly Advantage
The pipework can be laid in advance without the radiator to allow undisturbed progress of work.

Type 11 VM


| single-layer with one convection sheet | |||||
|---|---|---|---|---|---|
Height | 300 | 400 | 500 | 600 | 900 |
Length | up to 2400 | up to 2600 | up to 2000 | ||
Depth | 61 | ||||
Steps: all overall length starting with 400mm available in steps of 200mm, additionally 520, 720, 920, 1120 and 1320mm
Connections: 4 x internal thread G 1/2 and 2 x external thread G 3/4 bottom centre
Test positive pressure: 13 bar
Max. positive operating pressure: 10 bar
Max. operating temperature: 110 °C
Type 21 VM-S


| double-layer with one convection sheet | |||||
|---|---|---|---|---|---|
Height | 300 | 400 | 500 | 600 | 900 |
Length | up to 2400 | up to 3000 | up to 2000 | ||
Depth | 80 | ||||
Steps: all overall length starting with 400mm available in steps of 200mm, additionally 520, 720, 920, 1120 and 1320mm
Connections: 4 x internal thread G 1/2 and 2 x external thread G 3/4 bottom centre
Test positive pressure: 13 bar
Max. positive operating pressure: 10 bar
Max. operating temperature: 110 °C
Type 22 VM


| double-layer with two convection sheets | |||||
|---|---|---|---|---|---|
Height | 300 | 400 | 500 | 600 | 900 |
Length | up to 3000 | up to 2000 | |||
Depth | 105 | ||||
Steps: all overall length starting with 400mm available in steps of 200mm, additionally 520, 720, 920, 1120 and 1320mm
Connections: 4 x internal thread G 1/2 and 2 x external thread G 3/4 bottom centre
Test positive pressure: 13 bar
Max. positive operating pressure: 10 bar
Max. operating temperature: 110 °C
Type 33 VM


| three-layers with three convection sheets | |||||
|---|---|---|---|---|---|
Height | 300 | 400 | 500 | 600 | 900 |
Length | up to 3000 | up to 2200 | up to 1800 | ||
Depth | 166 | ||||
Steps: all overall length starting with 400 mm available in steps of 200mm, additionally 520, 720, 920, 1120 and 1320mm
Connections: 4 x internal thread G 1/2 and 2 x external thread G 3/4 bottom centre
Test positive pressure: 13 bar
Max. positive operating pressure: 10 bar
Max. operating temperature: 110 °C

Height
Length
Depth
Flow
Vent plug
Return
Drain plug
Blank plug