HYGIENE T6 RADIATORS

Proved suitability for the installation in rooms with particular hygienic requirements.


Thanks to innovative centre-connection technology and optimum energy efficiency, the T6 sets the standard for room heating, comfort and ease of use - advantages that will win over any customer!

APPLICATIONS:
Home heating/cooling and HVAC

PRODUCT OVERVIEW

The T6: revolution in radiators

Thanks to innovative centre-connection technology and optimum energy efficiency, the T6 sets the standard for room heating, comfort and ease of use - advantages that will win over any customer!

Connection advantage

Diagonal or in-line connection via a standardised connection position.

T6 connection advantage

Selection advantage

Even if the pipework is laid in advance, the choice of radiator can be changed at any time.

T6 selection advantage

Positioning advantage

Flexible thermostat position as desired, thanks to patented pipe guides.

T6 positioning advantage

Installation advantage

Cost-effective, attractive and safe installation options without limitations.

T6 installation advantage

Distance advantage

Flexible choice of models with a standardised distance between the connection and the wall.

T6 distance advantage

Assembly advantage

The pipework can be laid in advance without the radiator to allow undisturbed progress of work.

T6 assembly instructions

Varying dimensions and different designs regarding the number of layers lead to a wide range of models, suitable for different requiremets.

Type 10 VM

T6 hygiene radiator TYPE 10 VMT6 hygiene radiator TYPE 10 VM

single-layer
Height Height 300 400 500 600 900
Width Length up to 1200 up to 2400 up to 2600 up to 1400
Depth Depth 46

Steps: all overall length starting with 400 mm available in steps of 200 mm, additionally 520, 720, 920, 1120 and 1320 mm

Connections  Connections: 4 x G 1/2" I.G. and 2 x  G 3/4" A.G. lower edge, in the centre

Test positive pressure  Test positive pressure: 13 bar

Maximal positive operating pressure  Max. positive operating pressure: 10 bar

Maximal operating temperature  Max. operating temperature: 110 °C

Type 20 VM

T6 hygiene radiator TYPE 20VMT6 hygiene radiator TYPE 20VM

double-layer
Height Height 300 400 500 600 900
Width Length up to 2400 up to 3000 up to 2000
Depth Depth 80


Steps:
all overall length starting with 400 mm available in steps of 200 mm, additionally 520, 720, 920, 1120 and 1320 mm

Connections  Connections: 4 x G 1/2" I.G. and 2 x  G 3/4" A.G. lower edge, in the centre

Test positive pressure  Test positive pressure: 13 bar

Maximal positive operating pressure  Max. positive operating pressure: 10 bar

Maximal operating temperature  Max. operating temperature: 110 °C

Type 30 VM

T6 hygiene radiator TYPE 30 VMT6 hygiene radiator TYPE 30 VM

triple-layer
Height Height 300 400 500 600 900
Width Length up to 3000 up to 2200 up to 1800
Depth Depth 166


Steps:
all overall length starting with 400 mm available in steps of 200 mm, additionally 520, 720, 920, 1120 and 1320 mm

Connections  Connections: 4 x G 1/2" I.G. and 2 x  G 3/4" A.G. lower edge, in the centre

Test positive pressure  Test positive pressure: 13 bar

Maximal positive operating pressure  Max. positive operating pressure: 10 bar

Maximal operating temperature  Max. operating temperature: 110 °C

TECHNICAL INFORMATION
SPECIFICATIONS
IMAGES